Evocyl Horizontal

Evocyl Horizontal

Designed with performance in mind.

Produced to the same specification as Evocyl cylinders, the horizontal variant offers increased siting options allowing larger storage capacities in areas that would not normally accommodate standard vertical cylinders.
All horizontal cylinders are supplied with cradles.

Specification


  • 25 year cylinder warranty and 2 years parts warranty.
  • Sizes 120L to 300L in 545mm diameter.
  • Cylinder manufactured from high grade Duplex Stainless Steel.
  • Totally insulated with 50mm 100% CFC and HCFC free polyurethane to minimise heat loss.
  • Supplied with mounting cradles.
  • Supplied with high quality unvented installation components.
  • Indirect units supplied with fuel saving anti-Legionella dual stat.
  • 22mm threaded connections.
  • Efficient primary coil.
  • Slimline versions available.
  • Long-life 3kW Incoloy immersion heater supplied as standard. Upgrade to Titanium and or 6kw immersion heater on request.
  • Supplied with all safety controls as required by UK Building Regulations and Water Regulations.

Please note: Direct cylinders cannot be produced currently under new ErP legislation until further product testing has been completed. To aid with installations that will still utilise an electricity supply as a primary heating method, all indirect cylinders with capacity of 150L and above will come with 2 immersion heaters installed as standard.

Code TQHOI
0120
TQHOI
0150
TQHOI
0180
TQHOI
0210
TQHOI
0250
TQHOI
0300
Capacity (L) 120 150 180 210 250 300
Length 910 1110 1290 1480 1730 1990
Diameter 545 545 545 545 545 545
Hot Draw Off 215(A) 215(A) 215(A) 215(A) 215(A) 215(A)
Immersion 1 280(B) 350(B) 310(B) 340(B) 380(B) 445(B)
Boiler Return 370(C) 500(C) 405(C) 520(C) 530(C) 730(C)
T&P Valve 505(D) 665(D) 650(D) 745(D) 780(D) 980(D)
Boiler Flow 625(E) 830(E) 905(E) 1020(E) 1030(E) 1230(E)
Sec. Return - - - 1145(F) 1330(F) 1505(F)
Cold Feed 695(G) 900(G) 1090(G) 1270(G) 1515(G) 1715(G)
Stat Pocket 505(H) 665(H) 650(H) 745(H) 780(H) 980(H)
Product Weight
Empty
(KG)
Weight
Full
(KG)
Full Cold
Capacity
(Litres)
Reheat Indirect*
(Minutes)
Reheat 3KW
Immersion**
(Minutes)
Heat
Exchange***
(kW)

Dedicated
Solar
(Litres)
Standing
Loss
Cylinder
(kWh/24h)
Standing
Loss
Cylinder
(Watts)
ERP
Energy
Rating
ERP
Load
Profile
ERP
Energy
Efficiency
ηwh%
Annual
Energy
Usage
kWh/Year
Evocyl Horizontal 120
Indirect
33 150 117 15.82 116 16.54 - 1.29 54 C - - -
Evocyl Horizontal 150
Indirect
44 191 147 20.58 146 18.15 - 1.50 63 C - - -
Evocyl Horizontal 180
Indirect
47 223 176 22.43 176 17.31 - 1.71 71 C - - -
Evocyl Horizontal 210
Indirect
53 257 204 27.24 205 17.58 - 1.93 80 C - - -
Evocyl Horizontal 250
Indirect
58 303 245 31.64 245 18.07 - 2.13 89 C - - -
Evocyl Horizontal 300
Indirect
63 358 295 36.05 295 18.56 - 2.35 98 C - - -